Gentec-EO – Laser Power Meter & Laser Energy Meters

Laser Energy Meters

 

Product selector - Find the product you need easilyTechnical support - Need Technical Support ? Trade Shows worldwide
Laser Energy Meters
Specifications
Activate comparison ››››
To activate the comparison tool,
click on the box below the products
you are interested in to select
them. Then, just click on the Activate
comparison button.
WEEE/RoHS compliant Low Energy  For Integration  Small
Aperture 
Mid
Aperture 
Large
Aperture 
Xtreme
Energies
Large Beams 
XLE4 QE4 QE12 QE25 QE50 Calorimeters
Size Compact  Ultra Compact  12 x 12 mm  25 x 25 mm  50 x 50 mm  Custom 
Spectral Range 0.35 - 2.5 µm  0.19 - 20 µm  0.19 - 20 µm  0.19 - 20 µm  0.19 - 20 µm  Variable 
Energy Range (1) 30 nJ - 4 mJ  1 µJ - 27 mJ  0.7 µJ - 3.4 J  2 µJ - 20 J  10 µJ - 75 J  Up to 5000 J 
Max Pulse Widths 5 µs  10 - 100 µs  10 µs - 2 ms (2)  10 µs - 3 ms (2)  10 µs - 4 ms (3)  Custom 
Max. Rep. Rate (Hz) 2000  1200 - 6000  300 (3) - 6000  300 (4) - 6000  200 (4) - 4000  Single shots 
Technical Specifications            
Effective Aperture (mm) 4 Ø  3.8 Ø  12 x 12  25 x 25  50 x 50  Up to 420 x 427 
Rise Time (0-100%) 10 µs  20 - 200 µs  20 - 550 µs  20 - 550 µs  20 - 900 µs  Variable 
Sensitivity (V/J) 1100  150 - 200  60 - 100  10 - 20  3 - 4  Variable 
Calibration Uncertainly ± 4%  ± 3%  ± 3%  ± 3%  ± 3%  ± 5% 
Damage Thresholds (5)            
Max. Energy Density (1064 nm) 0.09 J/cm2  0.15 - 0.25 J/cm2  1 - 7 J/cm2  1 - 7 J/cm 2  1 - 7 J/cm2  Variable 
Max. Energy Density (266 nm) N/A  6 - 50 mJ/cm2  0.2 - 1 J/cm2  0.2 - 1 J/cm2  0.2 - 1 J/cm2  Variable 
Max. Avg. Power 0.4 W  0.3 W  12.5 W  30 W  45 W  N/A 
Available Modules            
Stand Alone            
Heatsink            
Absorber Types            
Black            
Broadband            
Metallic (High Rep. Rates)            
Glass            
Options            
Attenuators/Diffusers (for SOLO PE only)            
QE-X Amplifier            
Extra Long Pulse capabilities (msec)            

* : All values are for an entire family and not a specific product.  See the specification sheets for the values of individual detectors.
(1) : From Noise Equivalent Energy (NEE) to maximum measurable energy with QEA attenuator (when applicable).
(2) : On special request only.  Standard pulse widths are 10 µs, 150 µs and 400 µs.
(3) : On special request only.  Standard pulse widths are 10 µs, 225 µs and 675 µs.
(4) : This value is dependant of the maximum pulse width chosen and can be lower than specified in this table.
(5) : With QEA or QEAS attenuator when applicable.

Cette section est actuellement
en construction et sera
disponible sous peu.