Laser Power Meters

 

Product selector - Find the product you need easilyTechnical support - Need Technical Support ? Trade Shows worldwide
Laser Power Meters
Specifications
Activate comparison ››››
To activate the comparison tool,
click on the box below the products
you are interested in to select
them. Then, just click on the Activate
comparison button.
WEEE/RoHS compliant eXtreme Low Power
Thermopile-Based 
General Use
Fast Response 
High Power
Up to 60 mm Ø aperture 
General Use
Slim Profile 
High Average
Power Density
Slim Profile 
High Average
Power Density
100 kW/cm2 
High Peak
Power Density
100 GW/cm2 
Very High
Average
Power 
Quick Mesure
Hand Held 
XLP12 UP12E-H5 UP19K-H5(H9) UP25N(Z)-H9 UP55N-H9 UP55G-H12 UP17P-H5 UP17P-W5 UP19K-W5 UP50N-W9 UP19K-V HP60(70)A QPM Series
Size Compact  Ultra Compact  Compact  Mid  Large  Large  Ultra Thin (10.7 mm)  Ultra Thin (10.7 mm)  Compact  Large  Compact  Large  Mid to Large 
Optical Specifications                          
Spectral Range 0.19 - 20 μm  0.19 - 20 µm  0.19 - 20 µm  0.19 - 20 µm  0.19 - 20 µm  0.19 - 20 μm  0.19 - 20 μm  0.19 - 10 μm  0.19 - 10 µm  0.19 - 10 µm  0.19 - 2.5 µm  0.19 - 20 µm  0.25 - 11 µm 
Power Range (1) 1 μW - 2 W  1 mW - 110 W  1 mW - 190 W  3 mW - 300 W  5 mW - 400 W  15 mW - 500 W  1 mW - 7 W  1 mW - 7 W  1 mW - 85 W  5 mW - 85 W  2 mW - 35 W  3 - 10 kW  0.5 W - 10 kW 
Energy Range (2) (in energy mode) 12 μJ - 5 J  20 mJ - 5 J  20 mJ - 25 J  0.2 J - 40 J  0.25 J - 200 J  0.2 J - 200 J  20 mJ - 15 J  20 mJ - 200 J  20 mJ - 200 J  0.25 J - 500 J  20 mJ - 40 J    N/A 
Technical Specifications                          
Effective Aperture 12 mm Ø  12 mm Ø  19 mm Ø  25 mm Ø  55 mm Ø  55 mm Ø  17 mm Ø  17 mm Ø  17 mm Ø  50 mm Ø  18 mm Ø  60 - 70 mm Ø  20 - 65 mm Ø 
Response Time (nominal) 2.5 sec  0.3 sec  0.6 - 1.5 sec  1.3 sec  2.5 sec  2.8 sec  0.8 sec  1.4 sec  1.4 sec  3.5 sec  2.5 sec  7 - 9 sec  4 - 10 sec 
Sensitivity (natural) 200 mV/W  0.5 mV/W  0.2 - 0.6 mV/W  0.1 - 0.2 mV/W  0.1 mV/W  0.06 mV/W  0.6 mV/W  0.6 mV/W  0.6 mV/W  0.12 mV/W  0.3 mV/W  0.5 - 0.7 mV/W  N/A 
Calibration Uncertainly ± 2.5%  ± 2.5%  ± 2.5%  ± 2.5%  ± 2.5%  ± 2.5%  ± 2.5 %  ± 2.5 %  ± 2.5%  ± 2.5 %  ± 2.5%  ± 5%  ± 3 - 4 % 
Energy Mode                          
Sensitivity 25 mV/J  0.84 mV/J  0.65 mV/J  0.14 mV/J  0.028 mV/J  0.01 mV/J  0.7 mV/J  0.2 mV/J  0.33 mV/J  0.02 mV/J  0.1 mV/J    N/A 
Max Measurable Energy 5 J  5 J  15 J  40 J  200 J  200 J  15 J  200 J  200 J  500 J  40 J    N/A 
Noise Equivalent Energy 12 μJ  20 mJ  20 mJ  200 mJ  250 mJ  250 mJ  20 mJ  20 mJ  20 mJ  250 mJ  20 mJ    N/A 
Min Repetition Period 16 sec  1.5 sec  4 sec  4.6 sec  11.1 sec  14.3 sec  4 sec  5 sec  5 sec  11.1 sec  4.5 sec    N/A 
Max Pulse Width 300 ms  50 ms  88 ms  123 - 133 ms  433 ms  433 ms  88 ms  133 ms  133 ms  467 ms  90 ms    N/A 
Accuracy in Single Shot ± 5%  ± 5%  ± 5%  ± 5%  ± 5%  ± 5%  ± 5 %  ± 5 %  ± 5%  ± 5%  ± 5%    N/A 
Damage Thresholds                          
Max Avg. Power Density 1 kW/cm2 36 kW/cm2  36 - 45 kW/cm2  45 kW/cm2  45 kW/cm2  8 kW/cm2 @ 500 W  36 kW/cm2  100 kW/cm2  100 kW/cm2  100 kW/cm2  700 W/cm2  10 - 15 kW/cm 1.5 - 2.5 kW/cm2 
Max Energy Density (µs, ms) 5 J/cm2  5 J/cm2  5 - 9 J/cm2  9 J/cm2  9 J/cm2  9 J/cm2   5 J/cm2  100 J/cm2  100 J/cm2  100 J/cm2  40 J/cm2    N/A 
Max Energy Density (fs, ns) 1 J/cm2  1 J/cm2  1 J/cm2  1 J/cm2  1 J/cm2  1 J/cm2   1 J/cm2  1.1 J/cm2  1.1 J/cm2  1.1 J/cm2  6 J/cm2    N/A 
Available Modules                          
Stand Alone                          
Heatsink                          
Large Heatsink                          
Fan Cooled                          
Water Cooled                          
Monitor Compatibility                          
SOLO 2                         Come 
TUNER                         with 
UNO                         their 
S-LINK-2                         own 
P-LINK                         display 

* : All values are for an entire family and not a specific product. See the specification sheets for the values of individual detectors.
(1) : From Noise Equivalent Power (NEP) to maximum measurable power with the most effective cooling module.
(2) : From Noise Equivalent Energy (NEE) to maximum measurable energy with 360 µs pulses.

Cette section est actuellement
en construction et sera
disponible sous peu.