Quick guide to calculating laser fluence

What is laser fluence? It is a measure of energy delivered per unit area.

It tells you how concentrated a laser’s energy is. This is helpful to avoid busting damage thresholds, and to ensure good process quality. Energy density actually refers to the same concept. 

A commonly used unit for laser fluence is Joules per square centimeter (J/cm2).

How do you calculate fluence?

Calculating fluence is quite straightforward. It’s essentially just a simple division.

How the energy is distributed within the laser beam (i.e. the beam’s profile) has a large influence on the peak fluence. Hence, the division will have a slightly different scaling factor, depending on whether the laser has a flat-top profile, a gaussian profile, or something more irregular or exotic.

Try our laser fluence calculator

Gentec-EO's energy density and fluence calculator is publicly available and free to use. Bookmark the page and use it whenever it can save you time.

Measuring beam diameter... Harder than it looks!

In popular culture, lasers are little red dots with a sharp outline. There’s all the power in the world inside the red dot, and none at all outside of it. Measuring the diameter of such a laser is as straightforward as measuring the diameter of a circle on a piece of paper.

However, only flat-top lasers actually behave this way, and they represent a minority of lasers on the market.

Most lasers do not abruptly “turn off” at the edge of the beam. They are very bright in the middle, and then slowly get dimmer at the edges.

Because laser light tapers off gradually, the boundary between “inside the beam” and “outside the beam” can be a bit fuzzy.

This has led to many beam diameter definitions. The three you will typically come across are FWHM, 1/e2, and D4σ, and they make sense only if the beam is Gaussian. They represent the majority of beam profiles you will come across. Why, you might ask? Mostly because a Gaussian power distribution maintains its shape way more efficiently over a distance than any other profile.

All of that remains theories, and as you may already know, just as a laser beam spreads over distance, there can be a lot of divergence between theory and practice. So, to address that, there is what you call the M2 factor. This factor refers to how closely a laser beam resembles a theoretical Gaussian distribution (or bell curve).

Great models can be developed to characterize a beam, but there’s nothing like actually looking at it to assess its profile. Do not mistake what I just said here, even though a typical stormtrooper manages to miss its target indefinitely, if you look directly at your beam, even if you can’t see it, really serious damages can occur in a matter of fractions of seconds.

The best way to know your profile is to use the proper tool. There are plenty of options out there, but the most efficient would be a profiling camera. It would give you the exact intensity distribution in real time of your beam, including if there are any hotspots or defects.

Laser output measurement solves numerous problems for organizations across all industries. Download the guide below.

Gentec-EO's high-accuracy laser beam measurement instruments help engineers, scientists and technicians in all sorts of laser applications from the factory to the hospital, laboratory and research center. Learn about our solutions for these measurement types:

Flat-top lasers

Let’s start with the simplest of cases: flat-top lasers, where the energy is distributed perfectly evenly all across the beam.

Calculating the fluence is a piece of cake. Just divide the energy by the beam area.

For example, let’s calculate the fluence of a flat-top laser pulse of 10 mJ with a diameter of 4 mm. The surface of such a beam is π * ( 4 mm / 2 )2.

Dividing the pulse energy of 10 mJ by the surface (4 π mm2), we find that the fluence is 10 mJ / 4 π mm2 = 0.796 mJ / mm2, or 7.96*10-2 J/cm2.

Gaussian laser beams

The energy in a Gaussian beam is distributed unevenly, like mentionned before. There is much more power at the center of the beam than at the periphery.

Commonly, we will want the peak fluence, since it is peak fluence we need to watch out for to avoid going over damage thresholds.

The complicated way to get the fluence would be to integrate the energy distribution over the target area.

The simple way is, again, just a simple division. However, notice that this time there is a scaling factor of 2, energy is more concentrated in the center of the beam.

Peak Fluence = E / ( π w2 / 2 ), where w is the 1/e2 definition of the Gaussian beam radius.

Let’s calculate the peak fluence of the same laser as before (10 mJ pulses, 4 mm diameter), except this time considering that the profile is Gaussian, rather than flat-top.

Peak Fluence = 10 mJ / (π ( 4 mm / 2 )2 / 2) --> 10 mJ/ 2 π mm2 = 1.59 mJ/mm2, which is equivalent to 0.159 J/cm2.

Notice that the peak fluence of the Gaussian beam is twice as high as the fluence of a laser with the same basic parameters, but a flat-top profile.

Fuss-free fluence calculation for all beam profiles

You can get some ballpark figures using your laser manufacturer’s specs. However, for your production setup, don't be a stormtrooper, use accurate NIST-traceable energy detectors and the true beam size for consistent quality and maximal yield.


Gentec-EO
Gentec Electro-Optics is specialized in laser beam and terahertz source measurement and analysis. With an outstanding 50-year track record of innovation, developing and providing state-of the-art technologies to the laser market, Gentec-EO has become The Expert of the laser beam measurement field. For all sorts of laser applications from the factory to the hospital, laboratory and research center, Gentec-EO offers the broadest range of off-the-shelf and custom solutions, and stands ready to serve you now and in the future.