HP125A-15KW-HD-TUBE

P/N 205270M

High power detector for laser power measurement up to 15000 W. Includes extension tube to reduce back reflections.

    • QBH
    • 60 mm Ø
    • 100 mm Ø
    • 250 mm Ø
    • 125 x 125 mm
    • 280 x 280 mm
    • 500 x 500 mm
    • HD - 宽带、高功率
    • GD - 高功率密度,大锥度
    • GD - 高功率密度,小锥
    • HE - 宽带、高功率
    • 默认(不带TUBE)
    • 低(带TUBE)
    • 英制
    • 米制
    • Standard (DB15) + USB
    • BLU(DB15 + 无线)
HP125A-15KW-HD-TUBE HP125A-15KW-HD-TUBE HP125A-15KW-HD-TUBE HP125A-15KW-HD-TUBE HP125A-15KW-HD-TUBE HP125A-15KW-HD-TUBE HP125A-15KW-HD-TUBE HP125A-15KW-HD-TUBE HP125A-15KW-HD-TUBE HP125A-15KW-HD-TUBE HP125A-15KW-HD-TUBE HP125A-15KW-HD-TUBE HP125A-15KW-HD-TUBE HP125A-15KW-HD-TUBE HP125A-15KW-HD-TUBE HP125A-15KW-HD-TUBE HP125A-15KW-HD-TUBE HP125A-15KW-HD-TUBE

可追溯校准

Logo nist

Product family key features

High Power Handling

Handles up to 30 kW of continuous power with our standard models. Custom models are available for higher powers (See SUPER HP).

Stable Reading

Less sensitive to variations in water cooling temperature than any other high-power water-cooled meter on the market

Large Aperture

Our standard HP models (4KW, 12KW, 15KW and 30KW) have a very large effective aperture of up to 280 mm to accommodate even the largest laser beams. Larger apertures with various shapes are available upon request (See SUPER HP).

Available with YAG and CO2 Calibration

All HP Models can be calibrated at YAG and CO2 wavelengths with a calibration uncertainty of +/- 5%

Direct USB Connection to a PC

Each head comes with both a DB-15 connector (for use with a Gentec-EO monitor) and a USB2.0 output for direct connection to a PC.

 

Compatible displays & PC interfaces

  • MAESTRO MAESTRO

    Touchscreen display device for power & energy measurement. Single-channel, multiple outputs (USB, Ethernet, analog).

  • TUNER TUNER

    Display device with tuning needle for power measurement. Single-channel.

  • UNO UNO

    Economical display device for power measurement. Single-channel.

包括

  • Calibration certificate

  • Transport case

  • Personal wavelength correctionTM Certificate

  • Protective cover for optical surfaces

  • HP-W-ADAPTOR-3/8-10mm HP-W-ADAPTOR-3/8-10mm

    Adaptor for water fittings of HP series. Changes the thread from imperial (3/8") to metric (10 mm OD). One unit of this item corresponds to two of the described tubes.

Measurement capabilities

  • Maximum average power (continuous)

    15000 W
  • Minimum average power1

    500 W
  • Noise equivalent power2

    15 W
  • Spectral range

    0.193 - 20 μm
  • Typical rise time

    15 s
  • Typical power sensitivity

    0.13 mV/W
  • Power calibration uncertainty

    ±5 %
  • Repeatability

    ±2 %
  • Back reflections

    2 - 4 %
  • Linearity with power

    ±2 %
  • Linearity vs beam diameter

    ±1 %
  • Linearity vs beam position3

    ±1.0 %
    • 1. For lower powers, call your Gentec-EO representative.
    • 2. Nominal value. Actual value depends on electrical noise in the measurement system.
    • 3. For a beam size of 20% of the aperture area, moved across 80% of the aperture area.

Water requirements

  • Required cooling flow1

    (8 - 10) LPM < ±1 LPM/min
  • Temperature range

    15 – 25 °C
  • Rate of temperature change

    < ±3°C/min
  • Maximum water pressure

    413 kPa (60 psi)
    • 1. Contact Gentec-EO for clean deionized water cooling module option.

Damage thresholds

  • Maximum average power density1

    16 kW/cm²
    • 1. At 1064 nm, 1.07-1.08 µm and 10.6 µm, 500 W CW. Refer to user manual for damage threshold at other powers. May vary with wavelength and average power.

Controller and GUI specifications

  • Data display

    Real time, scope, needle, averaging, histogram and statistics
  • Analog output1

    0-2 Volts
  • Serial commands via

    USB
  • External power supply2

    Through USB or Gentec-EO displays & PC interfaces
  • Display type

    None
    • 1. 12 V maximum output signal available upon request.
    • 2. A USB power adaptor will be necessary if the HP is used with a DB-15 extension cable.

Physical characteristics

  • Cooling

    Water
  • Aperture diameter

    70 mm
  • Absorber

    HD
  • Dimensions

    153H x 153W x 272D mm
  • Weight

    10 kg

宽带 HD 吸收器:高性能,适用于大功率激光

我们的 HD 吸收器具有较高的损坏阈值和平坦的宽带光谱响应,适用于千瓦级大功率激光。带有这种吸收器的检测器用途广泛,可满足多种高功率测量需求。

可为客户提供以下优势:

  • 损坏阈值较高,设备损坏风险较低
  • 适用于测量各种高功率激光
 
 

与随附的 PC-Gentec-EO 软件一同使用

借助我们免费的专属软件 PC-Gentec-EO,您可以直接在电脑上读取测量结果。该软件支持以下产品系列:P-LINK、HP、INTEGRA、U-LINK 和 MAESTRO。

提供:

  • 实用显示:实时、范围、指针、平均值、直方图和统计数据
  • 数据记录和修正系数等实用功能
  • 提供多种统计数据:电流值、平均值、最大值、最小值、有效值稳定性、PTP 稳定性、重复率、平均功率和 STD 偏差

 

了解更多

利用 XNR AnticipationTM 加快测量速度

利用 XNR AnticipationTM,测量激光功率的速度可提高 10 倍(取决于型号)。我们的专利算法会查看信号增减的速度,并将其与校准数据相结合,从而预测结果。因此,计算和显示测量结果的速度要高于检测器的自然响应速度。

这为何很重要?

  • 每次测量可节省几秒到几十秒的时间
  • 运行中断时间缩短
  • 激光输出诊断加快
  • 生产率提升
  • 测量精度不打折扣

包括 NIST 可追溯校准

可追溯校准可将激光输出测量的读数追溯到美国国家标准与技术研究院(NIST)确定的已知国际测量标准。这确保了仪器测量的可靠性和准确性。

其优势包括:

  • 对组织内外其他仪器的测量结果进行有效比较,并对不同时间的测量结果进行比较
  • 符合法规或行业标准
  • 避免在运行中出现代价高昂的测量错误
  • 增强客户对激光系统的信心
  • 确保实验室实验的有效性
  • 利用我们提供的校准证书,轻松证明测量的准确性

 

了解更多

Related videos

所有视频

Compatible products you may need

Check if this product works for your laser

Measurement type:

1

Beam size

2

Laser type

3

Beam profile

COPYRIGHT ©2026 Gentec-eo Spektrum média