PRONTO-50-W5

P/N 203794

Portable laser power meter for up to 50 W.

    • 19 mm Ø
    • 55 mm Ø
    • 10 x 10 mm
    • W - Very high power density
    • H - Standard (up to 250 W)
    • EZ - Easy to clean
    • H - Standard (up to 10 kW)
    • H - Standard (up to 500 W)
    • H - Standard (up to 6 kW)
    • Silicon (up to 800 mW)
    • Power and Energy
    • Energy
    • Power
    • Standard (visible to NIR only)
    • Calibration YC
    • Calibration YCE
PRONTO-50-W5

Traceable calibration:

Logo nist

Product family key features

Pocket-Size

This mid to high power handheld probe is so compact it fits in your pocket!

Easy-to-Use

The touch screen color LCD allows for a friendly user interface. You can make a measurement with just the touch of a button!

User Settable

You can set the wavelength, brightness and screen orientation to adapt to your application.

Data Logging

Save your data to the internal memory and then transfer it to your PC over the USB connection.

From Low to High Powers

Thanks to a low noise level and high damage threshold, the PRONTO can measure powers from 1 W to 50 W.

Fully Calibrated

The PRONTO-50-W5 comes fully calibrated: every wavelength between 248 nm and 2.5 μm.

Hands-Free Operation

Place it on a flat surface or use one of the 2 threaded holes that we have integrated in the casing for safe use with optical stands.

Compatible stand

Included

  • MAE-USB MAE-USB

    USB cable for MAESTRO, U-LINK (USB), and PRONTO.

  • Calibration certificate

  • Transport case

  • Personal wavelength correctionTM Certificate

User manual

Measurement capabilities

  • Maximum average power

    50 W
  • Minimum average power

    0.5 W
  • Noise equivalent power

    4 mW
  • Spectral range1

    0.193 - 10 μm
  • Power calibration uncertainty

    ±3 %
  • Exposure time

    5 s
    • 1. For the calibrated spectral range, see the user manual.

Damage thresholds

  • Maximum average power density1

    100 kW/cm²
  • Maximum energy density2

    1.1 J/cm²
  • Maximum allowable casing temperature

    65 °C
    • 1. At 1064 nm, 10 W CW. May vary with wavelength and average power.
    • 2. At 1064 nm, 7 ns, 10 Hz. May vary with wavelength and pulse width.

Controller and GUI specifications

  • Battery type

    Rechargeable Li-ion
  • Battery life

    17 hours or 4,200 measurements (with brightness set at 25%)
  • Display resolution

    1 mW
  • Display size

    28.0 x 35.0 mm (128 x 160 pixels)
  • Display type

    Touch Screen Color LCD
  • Backlight

    Adjustable
  • Internet upgrades via

    USB
  • Data storage

    50,000 pts
  • Battery recharge via

    USB

Physical characteristics

  • Aperture diameter

    19 mm
  • Absorber

    W
  • Dimensions

    59.0W x 181.4L x 17.0D
  • Weight

    0.21 kg
  • Mounting holes

    2 x 8-32

CA$1,991.00

Request lead time before ordering.
CONTACT SALES

Measure extremely high average power density lasers with the W absorber

The W absorber can handle tightly focused beams thanks to its extremely high average power density damage threshold of 100 kW/cm2. It measures from UV to IR but is not suitable for CO2 laser wavelengths.

Customers enjoy:

  • Ideal for UV lasers and tightly focused beams
  • Very low risk of damaging the equipment

FEATURES

INTUITIVE USER INTERFACE

PROTECTIVE CASING INCLUDED

HANDS-FREE OPERATION

DATA TRANSFER TO PC

Leverage serial commands

Use our serial commands to communicate directly with the meter without using Gentec-EO's software. You can do so using a terminal emulator software, like PuTTY, or you can just integrate them directly into your own software. All essential functions of the meter are covered by a command. Refer to the user manual of the meter for the list of all commands available.

Benefits:

  • Build your own software
  • Suit your unique laser application requirements
  • Automate your measurements

NIST-TRACEABLE CALIBRATION INCLUDED

Traceable calibration provides the ability to trace the readings of laser output measurements to known international measurement standards determined by the National Institute of Standards and Technology (NIST). This ensures that the measurements taken by the instruments are reliable and accurate.

Benefits include:

  • Make valid comparisons of measurements taken by other instruments inside and outside your organization and over time
  • Comply with regulations or conform to industry standards
  • Avoid costly measurement mistakes in your operations
  • Improve customer confidence in your laser systems
  • Ensure laboratory experiment validity
  • Demonstrate measurement accuracy easily with the calibration certificate we provide
 

Related videos

All videos

FAQ

  • What is this product used for?

    The PRONTO-50-W5 is used to measure laser power up to 50 W with a compact handheld touchscreen meter. It is especially useful for applications with tighter or higher power-density beams because its W absorber is designed for high average power density.
  • What are its key specifications?

    Key PRONTO-50-W5 specifications include maximum average power of 50 W, minimum average power of 0.5 W, noise equivalent power of 4 mW, 19 mm aperture diameter, 0.193–10 µm spectral range, 248 nm–2.5 µm calibrated range, ±3% power calibration uncertainty, 5 s exposure time, 1 mW display resolution, W absorber, 50,000-point data storage, and 17-hour battery life or 4,200 measurements at 25% brightness.
  • How do I choose this model vs another?

    Choose the PRONTO-50-W5 when your application is below 50 W but needs a W absorber for high average power density or tightly focused beams. Choose a PRONTO-250 or PRONTO-250-FLEX model if you need up to 250 W, or a high-power PRONTO model if your laser exceeds that range.
  • What accessories/options are compatible?

    Compatible accessories/options include the STAND-S-233 stand, MAE-USB cable, PRONTO data-transfer software, and NAN-915 protective carrying case. The device includes mounting holes for hands-free optical setup.
  • What should I know before buying?

    Before buying the PRONTO-50-W5, confirm that your laser power is within the 0.5 W to 50 W range, that your wavelength fits the 0.193–10 µm spectral range, and that the W absorber is appropriate for your laser. Note that this model is not intended for CO₂ laser wavelengths.

Compatible products you may need

*Does not include shipping fees, import fees or local representation. Request quote for full details and local sales contact.

Check if this product works for your laser

Measurement type:

1

Beam size

2

Laser type

3

Beam profile

COPYRIGHT ©2026 Gentec-eo Spektrum média