HP60A-15KW-GD-IMP-D0

P/N 205219I

High power detector for laser power measurement up to 15 000 W.

    • QBH
    • 60 mm Ø
    • 100 mm Ø
    • 250 mm Ø
    • 125 x 125 mm
    • 280 x 280 mm
    • 500 x 500 mm
    • GD - High power density, small cone
    • GD - High power density, large cone
    • HD - Broadband, high power
    • HE - Broadband, high power
    • Standard (without TUBE)
    • Low (with TUBE)
    • Imperial
    • Metric
    • Standard (DB15) + USB
    • BLU (DB15 + wireless)
HP60A-15KW-GD-IMP-D0 HP60A-15KW-GD-IMP-D0 HP60A-15KW-GD-IMP-D0 HP60A-15KW-GD-IMP-D0 HP60A-15KW-GD-IMP-D0 HP60A-15KW-GD-IMP-D0 HP60A-15KW-GD-IMP-D0 HP60A-15KW-GD-IMP-D0 HP60A-15KW-GD-IMP-D0 HP60A-15KW-GD-IMP-D0 HP60A-15KW-GD-IMP-D0 HP60A-15KW-GD-IMP-D0 HP60A-15KW-GD-IMP-D0 HP60A-15KW-GD-IMP-D0 HP60A-15KW-GD-IMP-D0 HP60A-15KW-GD-IMP-D0 HP60A-15KW-GD-IMP-D0 HP60A-15KW-GD-IMP-D0

Traceable calibration:

Logo nist

Product family key features

High Power Handling

Handles up to 30 kW of continuous power with our standard models. Custom models are available for higher powers (See SUPER HP).

Stable Reading

Less sensitive to variations in water cooling temperature than any other high-power water-cooled meter on the market

Large Aperture

Our standard HP models (4KW, 12KW, 15KW and 30KW) have a very large effective aperture of up to 280 mm to accommodate even the largest laser beams. Larger apertures with various shapes are available upon request (See SUPER HP).

Available with YAG and CO2 Calibration

All HP Models can be calibrated at YAG and CO2 wavelengths with a calibration uncertainty of +/- 5%

Direct USB Connection to a PC

Each head comes with both a DB-15 connector (for use with a Gentec-EO monitor) and a USB2.0 output for direct connection to a PC.

 

Compatible displays & PC interfaces

  • MAESTRO MAESTRO

    Touchscreen display device for power & energy measurement. Single-channel, multiple outputs (USB, Ethernet, analog).

  • TUNER TUNER

    Display device with tuning needle for power measurement. Single-channel.

  • UNO UNO

    Economical display device for power measurement. Single-channel.

Included

  • Calibration certificate

  • Transport case

  • Personal wavelength correctionTM Certificate

  • Protective cover for optical surfaces

Measurement capabilities

  • Maximum average power (continuous)

    15000 W
  • Minimum average power1

    500 W
  • Noise equivalent power2

    15 W
  • Spectral range

    0.8 - 12 μm
  • Typical rise time

    15 s
  • Power calibration uncertainty

    ±5 %
  • Repeatability

    ±2 %
  • Back reflections

    5 - 10 %
  • Linearity with power

    ±2 %
  • Linearity vs beam diameter

    ±2.5 %
  • Linearity vs beam position3

    ±4 %
    • 1. For lower powers, call your Gentec-EO representative.
    • 2. Nominal value. Actual value depends on electrical noise in the measurement system.
    • 3. For a beam size of 20% of the aperture area, moved across 80% of the aperture area.

Water requirements

  • Required cooling flow1

    (8 - 10) LPM < ±1 LPM/min
  • Temperature range

    15 – 25 °C
  • Rate of temperature change

    < ±3°C/min
  • Maximum water pressure

    413 kPa (60 psi)
    • 1. Contact Gentec-EO for clean deionized water cooling module option.

Damage thresholds

  • Maximum average power density1

    80 kW/cm²
    • 1. At 1064 nm, 1.07-1.08 µm and 10.6 µm, 500 W CW. Refer to user manual for damage threshold at other powers. May vary with wavelength and average power.

Controller and GUI specifications

  • Data display

    Real time, scope, needle, averaging, histogram and statistics
  • Analog output1

    0-2 Volts
  • Serial commands via

    USB
  • External power supply2

    Through USB or Gentec-EO displays & PC interfaces
  • Display type

    None
    • 1. 12 V maximum output signal available upon request.
    • 2. A USB power adaptor will be necessary if the HP is used with a DB-15 extension cable.

Physical characteristics

  • Cooling

    Water
  • Aperture diameter

    60 mm
  • Absorber

    GD
  • Dimensions

    153H x 153W x 97D mm
  • Weight

    10 kg

CA$12,645.00*

Gold cone absorber: Measure high-power lasers with low back reflections

The most remarkable feature of the GD absorber is that it has the highest damage thresholds for the average power density of the HP series, making it an ideal choice for small, high-power beams. It also features lower back reflections than our standard H absorber.

Customers enjoy:

  • Safer work environment when working with very high-power lasers
  • Kilowatt-level power measurement
  • Highest average power density damage threshold
  • Low risk of damaging the equipment with your laser
 
 

Use it with our included PC-Gentec-EO software

Read your measurements directly on your PC thanks to our free proprietary software PC-Gentec-EO. The software supports the following product series: P-LINK, HP, INTEGRA, U-LINK, and MAESTRO.

Enjoy:

  • Practical displays: real-time, scope, needle, averaging, histogram, and statistics
  • Useful features such as data logging and correction factors
  • Many statistics available: current value, average value, maximum value, minimum value, RMS stability, PTP stability, repetition rate, average power, and STD deviation

 

Learn more

Faster measurement with XNR AnticipationTM

Measure laser power up to 10x faster (model-dependant) with XNR AnticipationTM. Our proprietary algorithm looks at the rate at which the signal increases or decreases and combines this with calibration data to predict the result. The measurement is therefore calculated and displayed faster than the natural response of the detector.

Why does it matter?

  • Save several seconds to tens of seconds for each measurement
  • Shorter operation interruption
  • Faster laser output diagnostics
  • Increased productivity
  • No compromise on measurement accuracy

NIST-TRACEABLE CALIBRATION INCLUDED

Traceable calibration provides the ability to trace the readings of laser output measurements to known international measurement standards determined by the National Institute of Standards and Technology (NIST). This ensures that the measurements taken by the instruments are reliable and accurate.

Benefits include:

  • Make valid comparisons of measurements taken by other instruments inside and outside your organization and over time
  • Comply with regulations or conform to industry standards
  • Avoid costly measurement mistakes in your operations
  • Improve customer confidence in your laser systems
  • Ensure laboratory experiment validity
  • Demonstrate measurement accuracy easily with the calibration certificate we provide
 

Related videos

All videos

Compatible products you may need

*Does not include shipping fees, import fees or local representation. Request quote for full details and local sales contact.

Your item has been added to your cart!

You might need these specific products to be able to use the placeholder only.

Compatible products

No compatible product

Check if this product works for your laser

Measurement type:

1

Beam size

2

Laser type

3

Beam profile

COPYRIGHT ©2024 Gentec-eo Spektrum média