UP17P-6S-W5-D0

P/N 201021

Thermal detector for laser power measurement up to 6 W.

    • 10 mm Ø
    • 12 mm Ø
    • 16 - 19 mm Ø
    • 25 mm Ø
    • 50 - 55 mm Ø
    • Convection (up to 15 W)
    • Heatsink (up to 30 W)
    • Large Heatsink (up to 50 W)
    • Fan (up to 110 W)
    • Water (up to 200 W)
    • Convection - compact casing (up to 6 W)
    • Water – large casing
    • H - Broadband
    • W - Very high power density
    • QED - High energy density
    • F - IR filter
    • HD - Broadband, high power
    • VP - Ultrashort Pulses
    • Standard
    • INTEGRA (USB)
    • INTEGRA (RS-232)
    • INTEGRA (USB with external trigger)
    • BLU (wireless)
UP17P-6S-W5-D0 UP17P-6S-W5-D0 UP17P-6S-W5-D0 UP17P-6S-W5-D0 UP17P-6S-W5-D0 UP17P-6S-W5-D0 UP17P-6S-W5-D0 UP17P-6S-W5-D0 UP17P-6S-W5-D0 UP17P-6S-W5-D0 UP17P-6S-W5-D0 UP17P-6S-W5-D0 UP17P-6S-W5-D0 UP17P-6S-W5-D0 UP17P-6S-W5-D0 UP17P-6S-W5-D0 UP17P-6S-W5-D0 UP17P-6S-W5-D0

Available with

Logo Integra

Key features

Ultra Thin Casing

Only 10.7 mm thick!

Choice Between 2 Absorbers

  • H5: 36 kW/cm2
  • W5: unequalled 100 kW/cm2

High “Power to Size” Ratio

6 W continuous reading

Energy Mode

Measure single shot energy up to 200 J (with the W5 version)

Smart Interface

Containing all the calibration data

Compatible stand

Compatible displays & PC interfaces

  • MIRO ALTITUDE MIRO ALTITUDE

    Touchscreen display device for power & energy measurement. Single-channel.

  • MAESTRO MAESTRO

    Touchscreen display device for power & energy measurement. Single-channel, multiple outputs (USB, Ethernet, analog).

  • U-LINK (USB) U-LINK (USB)

    PC interface for power & energy measurement. Single-channel, USB output.

  • U-LINK (RS-232) U-LINK (RS-232)

    PC interface for power & energy measurement. Single-channel, RS-232 output.

  • INTEGRA INTEGRA

    Embedded PC interface for power & energy measurement. Can only be purchased as a detector output option.

  • TUNER TUNER

    Display device with tuning needle for power measurement. Single-channel.

  • UNO UNO

    Economical display device for power measurement. Single-channel.

  • P-LINK (USB) P-LINK (USB)

    PC interface for power measurement. Single-channel, USB output.

  • P-LINK (RS-232) P-LINK (RS-232)

    PC interface for power measurement. Single-channel, RS-232 output.

  • S-LINK-1 (Ethernet) S-LINK-1 (Ethernet)

    PC interface for power & energy measurement. Single-channel, USB & Ethernet output.

  • S-LINK-2 (Ethernet) S-LINK-2 (Ethernet)

    PC interface for power & energy measurement. Dual-channel, USB & Ethernet output.

  • M-LINK M-LINK

    PC interface for power & energy measurement. Single-channel, USB output.

  • S-LINK-1 S-LINK-1

    PC interface for power & energy measurement. Single-channel, USB output.

  • S-LINK-2 S-LINK-2

    PC interface for power & energy measurement. Dual-channel, USB output.

  • P-LINK-4 (USB) P-LINK-4 (USB)

    PC interface for power measurement. Four channels.

Measurement capabilities

  • Maximum average power (continuous)

    6 W
  • Maximum average power (1 minute)

    7 W
  • Noise equivalent power1

    1 mW
  • Spectral range2

    0.193 - 10 μm
  • Typical rise time3

    1.4 s
  • Typical power sensitivity4

    0.6 mV/W
  • Power calibration uncertainty5

    ±2.5 %
  • Repeatability

    ±0.5 %
    • 1. Nominal value, actual value depends on electrical noise in the measurement system.
    • 2. For the calibrated spectral range, see the user manual.
    • 3. With anticipation.
    • 4. Into 100 kΩ load. Maximum output voltage = sensitivity x maximum power.
    • 5. Including linearity with power.

Measurement capabilities (Energy mode)

  • Typical energy sensitivity

    0.2 mV/J
  • Maximum measurable energy1

    200 J
  • Noise equivalent energy2

    0.02 J
  • Minimum repetition period

    5 s
  • Maximum pulse width

    133 ms
  • Energy calibration uncertainty3

    ±5 %
    • 1. For 360 μs pulses. Higher pulse energy possible for long pulses (ms), less for short pulses (ns).
    • 2. Nominal value, actual value depends on electrical noise in the measurement system.
    • 3. When single-shot energy calibration is purchased
  • }

Damage thresholds

  • Maximum average power density1

    100 kW/cm²
  • Maximum energy density2

    1.1 J/cm²
    • 1. At 1064 nm, 10 W CW. May vary with wavelength and average power.
    • 2. At 1064 nm, 7 ns, 10 Hz. May vary with wavelength and pulse width.

Physical characteristics

  • Cooling

    Convection
  • Aperture diameter

    17 mm
  • Absorber

    W
  • Dimensions

    46H x 46W x 10.7D mm
  • Weight

    0.1 kg

Related videos

Compatible products you may need

Your item has been added to your cart!

You might need these specific products to be able to use the placeholder only.

Compatible products

No compatible product

Check if this product works for your laser

Measurement type:

1

Beam size

2

Laser type

3

Beam profile

COPYRIGHT ©2023 Gentec-eo Spektrum média