XLP12-3S-H2-D0

P/N 201032

Thermopile detector for laser power measurement up to 3 W.

    • 10 mm Ø
    • 12 mm Ø
    • 16 - 19 mm Ø
    • 25 mm Ø
    • 50 - 55 mm Ø
    • Convection (up to 3 W)
    • Convection (up to 10 W)
    • Heatsink (up to 20 W)
    • Water (up to 70 W)
    • Convection - compact casing
    • Fan
    • Large Heatsink
    • Water – large casing
    • H - Broadband
    • F - IR filter
    • VP - Ultrashort Pulses
    • HD - Broadband, high power
    • QED - High energy density
    • W - Very high power density
    • Standard
    • INTEGRA (USB)
    • INTEGRA (RS-232)
    • INTEGRA (USB with external trigger)
    • BLU (wireless)
XLP12-3S-H2-D0 XLP12-3S-H2-D0 XLP12-3S-H2-D0 XLP12-3S-H2-D0 XLP12-3S-H2-D0 XLP12-3S-H2-D0 XLP12-3S-H2-D0 XLP12-3S-H2-D0 XLP12-3S-H2-D0 XLP12-3S-H2-D0 XLP12-3S-H2-D0 XLP12-3S-H2-D0 XLP12-3S-H2-D0 XLP12-3S-H2-D0 XLP12-3S-H2-D0 XLP12-3S-H2-D0 XLP12-3S-H2-D0 XLP12-3S-H2-D0

Available with

Logo blu Logo Integra

Key features

Low Power Thermopile

Noise level of a photo detector with the large bandwidth and high power capacity of a thermal device

Minimal Thermal Drift

Only 6 µW/°C (with the IR filter)

High Sensitivity

200 mV/W (without the IR filter)

Special Model for Ultrashort Pulses

VP (volume absorber) version is perfect for low power lasers with ultrashort pulses (ps and fs)

IR Filter (XLPF12 Model)

Removes unwanted IR interference

Isolation Tube

Eliminates power fluctuations created by air turbulence

Compatible stand

Compatible displays & PC interfaces

  • MIRO ALTITUDE MIRO ALTITUDE

    Touchscreen display device for power & energy measurement. Single-channel.

  • MAESTRO MAESTRO

    Touchscreen display device for power & energy measurement. Single-channel, multiple outputs (USB, Ethernet, analog).

  • U-LINK (USB) U-LINK (USB)

    PC interface for power & energy measurement. Single-channel, USB output.

  • U-LINK (RS-232) U-LINK (RS-232)

    PC interface for power & energy measurement. Single-channel, RS-232 output.

  • BLU BLU

    Embedded wireless interface for power measurement. Can only be purchased as a detector output option.

  • TUNER TUNER

    Display device with tuning needle for power measurement. Single-channel.

  • UNO UNO

    Economical display device for power measurement. Single-channel.

  • P-LINK (USB) P-LINK (USB)

    PC interface for power measurement. Single-channel, USB output.

  • P-LINK (RS-232) P-LINK (RS-232)

    PC interface for power measurement. Single-channel, RS-232 output.

  • S-LINK-1 (Ethernet) S-LINK-1 (Ethernet)

    PC interface for power & energy measurement. Single-channel, USB & Ethernet output.

  • S-LINK-2 (Ethernet) S-LINK-2 (Ethernet)

    PC interface for power & energy measurement. Dual-channel, USB & Ethernet output.

  • M-LINK M-LINK

    PC interface for power & energy measurement. Single-channel, USB output.

  • S-LINK-1 S-LINK-1

    PC interface for power & energy measurement. Single-channel, USB output.

  • S-LINK-2 S-LINK-2

    PC interface for power & energy measurement. Dual-channel, USB output.

  • P-LINK-4 (USB) P-LINK-4 (USB)

    PC interface for power measurement. Four channels.

Measurement capabilities

  • Maximum average power (continuous)

    3 W
  • Maximum average power (1 minute)

    3 W
  • Noise equivalent power1

    0.5 μW
  • Spectral range2

    0.193 - 20 μm
  • Typical rise time3

    2.5 s
  • Typical power sensitivity4

    200 mV/W
  • Power calibration uncertainty5

    ±2.5 %
  • Repeatability

    ±0.5 %
  • Thermal drift6

    12 μW/°C
    • 1. Nominal value, actual value depends on electrical noise in the measurement system.
    • 2. For the calibrated spectral range, see the user manual.
    • 3. With anticipation.
    • 4. Into 100 kΩ load. Maximum output voltage = sensitivity x maximum power.
    • 5. Including linearity with power.
    • 6. With MAESTRO.

Measurement capabilities (Energy mode)

  • Typical energy sensitivity

    25 mV/J
  • Maximum measurable energy1

    5 J
  • Noise equivalent energy2

    12 μJ
  • Minimum repetition period

    16 s
  • Maximum pulse width

    300 ms
  • Energy calibration uncertainty3

    ±5 %
    • 1. For 360 μs pulses. Higher pulse energy possible for long pulses (ms), less for short pulses (ns).
    • 2. Nominal value, actual value depends on electrical noise in the measurement system.
    • 3. When single-shot energy calibration is purchased
  • }

Damage thresholds

  • Maximum average power density1

    1 kW/cm²
  • Maximum energy density2

    1 J/cm²
    • 1. At 1064 nm, 1 W CW. May vary with wavelength and average power.
    • 2. At 1064 nm, 7 ns, 10 Hz. May vary with wavelength and pulse width.

Physical characteristics

  • Cooling

    Convection
  • Aperture diameter

    12 mm
  • Absorber

    H2
  • Dimensions

    73H x 73W x 20D mm (72D mm with tube)
  • Weight

    0.31 kg

CA$1,388.90*

Related videos

Compatible products you may need

*Does not include shipping fees, import fees or local representation. Request quote for full details and local sales contact.

Your item has been added to your cart!

You might need these specific products to be able to use the placeholder only.

Compatible products

No compatible product

Check if this product works for your laser

Measurement type:

1

Beam size

2

Laser type

3

Beam profile

COPYRIGHT ©2023 Gentec-eo Spektrum média